HVAC systems consume nearly 40% of electrical energy in commercial and industrial applications, making installing and running an energy-efficient system crucial. Sandeep Rane, Director of Sheetal Academy, shares the importance of energy efficiency in HVAC systems. 

HVAC systems consume almost 40% of electrical energy in any commercial application and are also a major power consumer in industrial applications. Hence, it is essential to install and run an energy-efficient HVAC system. Planning starts at the project stage and continues through operation and maintenance. Selecting the proper equipment for the project is very important. The main equipment of any HVAC system is the chiller, AHU, pumps, and cooling tower (in the case of a water-cooled chiller).

Opting for chillers with flooded-type evaporators whenever possible is ideal. C.O.P. 5.6 TO 6.2 and electrical consumption of 0.57 kW/ton. At full load as per AHRI 550/590 (IP) and 551/591(SI). Standard rating condition of IPLV.IP as low as 0.34 KW/TON. Select chillers according to:

  • Oil-free operation
  • Chillers with inbuilt VSD (Variable Speed Drive). And 2-stage compressor design to achieve full load and part load performance. 
  • Always select the soft start module, which reduces current at start-up.
  • Refrigerator-cooled compressors are covered under AHRI 550/590 and 551/591, and absorption chillers are covered under AHRI Standard 560. 

Air-handling unit (AHU)

Always select a double-skin modular AHU with an insulation thickness of 25 mm to 50 mm, 40 kg/m3 density and thermal conductivity of K=0.07 w/moK.

I always choose new EC motors for AHUfollowed by traditional belt-driven motors, new axial fans, and centrifugal fansI check that AHU performance complies with industrial standards—AMCA 210 AHRI 430 (ASHRAE 51). Also, I prefer direct-drive fans to belt-driven fans and use Energy Star equipment. 

Install the correct-sized air compressor for VSD, comply with ASHRAE 90.1 requirements, and use low-emissivity glass, specifically double-pane glass, as an insulator in building projects.

Advertising

OEM Android App

Your future advertising space? Our media data

In operation and maintenance

Conduct regular energy audits to manage energy consumption by collecting energy data for all HVAC equipment. There must also be a proper schedule for preventive and predictive maintenance.

A neglected or poorly maintained cooling tower can decrease a chiller’s efficiency by 10% to 35%. In the case of an air-cooled chiller, a dirty condenser coil will drop the chiller’s efficiency by 5% to 15%.  

In a water-cooled condenser, a drop of 1 degree Fahrenheit in the cooling water temperature of the cooling tower can increase the chiller efficiency by 1% to 2 %. Proper annual chemical cleaning of the inside of the condenser and evaporator coil pipes can enhance heat transfer, resulting in a 5% to 15% energy saving -KW/TON.

Check for pipe insulation regularly and maintain proper chilled water pipe insulation. Worn-out insulation results in a loss of the chiller’s thermal efficiency. For the air Compressor, check for air leakages and a drop in pressure in ideal condition.  

Regular inspection and maintaining the proper insulation of chilled water pipes is essential. The loss of thermal efficiency of a chiller can be attributed to worn-out insulation, and the air compressor is being checked for air leakages and pressure drops in optimal condition.

Cookie Consent

We use cookies to personalize your experience. By continuing to visit this website you agree to our Terms & Conditions, Privacy Policy and Cookie Policy.

OEM Update QR Code
OEM Update QR Code

Events

AMTS China
AMTS China
India Fastener Show
India Fastener Show
India Manufacturing Show
India Manufacturing Show
4th IFFE EXPO 2025
4th IFFE EXPO 2025
Factory Automation Expo 2025
Factory Automation Expo 2025
17th ENGIMACH 2025
17th ENGIMACH 2025
LWOP
LWOP
IFAT India 2025
IFAT India 2025
Laser Engineering Technology Expo
Laser Engineering Technology Expo
Auto EV Bharat 2025
Auto EV Bharat 2025

eMagazine June 2025

eMagazine June 2025
eMagazine June 2025

Do you want to advertise here? Contact us

Our Sponsors

B&R Automation
B&R Automation
Pragati Gears
Pragati Gears
Carl Zeiss India
Carl Zeiss India
Maco-c
Maco-c
igus
igus
Delta Electric
Delta Electric
Ravik Engineers Private Limited
Ravik Engineers Private Limited
Cumi
Cumi
Marvel Machinery
Marvel Machinery
UNP Polyvalves India Pvt Ltd
UNP Polyvalves India Pvt Ltd
ENS Oils & Lubricants
ENS Oils & Lubricants
Super Slides
Super Slides
Quality Spares Center
Quality Spares Center
IMTMA- IMTEX 24
IMTMA- IMTEX 24
ACE Micromatic Group
ACE Micromatic Group
Accu Sharp
Accu Sharp
Poonam 3D Prints
Poonam 3D Prints
Chicago Pneumatic Tools
Chicago Pneumatic Tools
Shree Rapid
Shree Rapid
Yash Dynamice
Yash Dynamice
Amsak Cranes
Amsak Cranes
Molygraph
Molygraph
Exorint
Exorint
Exon mobil
Exon mobil