July 11, 2016 6:00 pm

  Evaporative cooling towers are key components in the effective operation of plants in the electric power, industrial process and manufacturing industries. They also are essential in the heating, ventilation and air conditioning (HVAC) systems that provide climate control in large facility complexes, such as educational and corporate campuses; casinos, hotels and convention facilities; data centres, and government, research and medical buildings. The proper control and treatment of cooling water is essential for efficient, safe and economical operations. Chemicals are fed to these systems that protect against fouling, corrosion and microbiological contamination. The proper dosage of these key chemicals is determined by having accurate information on the system make-up and blowdown water.
To achieve effective cooling through the cooling tower, it is necessary to maintain proper design flow through the cooling tower and thus provide adequate cooling of the system. Insufficient cooling water can affect critical equipment or building climate control. Accurate flow meters are the most effective tool to achieve reliable flow results and control system costs.
Here are three ways to optimise cooling water management with flow meters:Tip 1: Install a flow meter at the plant water intake source, which can turn the meters sub-meters. Comparing the flow data on all three lines helps identify potential water leaks and determine the system water balance plus other system issues.
Tip 2: Install flow meters upstream from pumps to provide flow data alerting the system to low flow situations leading to potential pump problems caused by low flow conditions. Otherwise, the result can be expensive pump repairs or even system shutdowns.
Tip 3: Accurate flow information collected from both the blowdown and make- up water lines can be used to calculate rates for evaporation, cycles of concentration and cooling water chemical treatment rates.Tracking these related factors is important to the assessment and improvement of a system’s water treatment program. For example, maintaining the highest cycles of concentration can offer significant savings on cooling water treatment costs. Having accurate blowdown and make-up flow rate data is essential in achieving this goal. The flow data translates into savings on chemicals, sewage fees and associated energy costs related to cooling water usage.
Flow Meter Technologies Different flow meter technologies have their advantages and disadvantages, depending on the fluid and application. Cooling tower and HVAC systems require the ability to measure flow to +0.5 per cent accuracy in high instrumentation is tight, and low maintenance and long life are essential.McCrometer’s FPI Mag Electro
Magnetic flow meter meets the accuracy requirement in water for cooling tower service with its accurate sensing across the full diameter of the pipe. The meter installs without cutting pipe, welding flanges, de-watering lines or interrupting service. This reduces installation time and costs by up to 45 percent over traditional full pipe flow meter installations.
Conclusions When choosing a new or replacement flow meter for service in cooling tower systems, be sure to consider the meter’s accuracy, ease of installation, maintenance requirements and life of the instrument. Flow measurement at multiple points in cooling tower and HVAC systems is a best industry practice to minimise – water consumption, energy expenses, the cost of water treatment consumables and repairs to pumps and other equipment.                                                                   
For Further details contactToshniwal Hyvac Pvt Ltd,267, Kilpauk Garden Road Chennai – 600010Contact: +91 44 2644562 / 8983 Email: sales@toshniwal.netWebsite: www.toshniwal.net

Cookie Consent

We use cookies to personalize your experience. By continuing to visit this website you agree to our Terms & Conditions, Privacy Policy and Cookie Policy.

Tags:
OEM Update QR Code
OEM Update QR Code

Events

Intralogistics and Warehousing Expo
Intralogistics and Warehousing Expo
Metal Forming Expo
Metal Forming Expo
amtex
amtex
Fastener Fair India
Fastener Fair India
Himtex 2024
Himtex 2024
Pharma India Expo
Pharma India Expo
World of Photonics India
World of Photonics India
IFFE Expo
IFFE Expo
India Essen Welding and Cutting Expo
India Essen Welding and Cutting Expo

eMagazine April 2024

eMagazine April 2024
eMagazine April 2024

Your future advertising space? Our media data

Our Sponsors

Carl Zeiss India
Carl Zeiss India
STMCNC
STMPC
Lakshmi Machine Works Limited
Lakshmi Machine Works Limited
BR Automation
BR Automation
Pragati Gears
Pragati Gears
Pilz India
Pilz India
Fuji Electric India
Fuji Electric India
Testo-India
Testo-India
AMF
AMF
Bibus India
Bibus India
Mallcom
Mallcom
HPL Electric Power
HPL Electric Power
PMT Machines Ltd
PMT Machines Ltd
Igus India Pvt Ltd
Igus India Pvt Ltd
Sdtronics
Sdtronics
Vega India Level Ltd
Vega India Level Ltd
Wago Pvt Ltd
Wago Pvt Ltd
Mecc alte
Mecc alte
Hosabettu Heavy Machinery LLP
Hosabettu Heavy Machinery LLP
Chicago Pneumatic Tools
Chicago Pneumatic Tools
Concord Hydraulics
Concord Hydraulics
Fenwick and Ravi
Fenwick and Ravi
MMC Hardmetal Pvt Ltd
MMC Hardmetal Pvt Ltd
Radicon Powerbuild
Radicon Powerbuild
Mennekes
Mennekes
Red Lion
Red Lion
EAPL
Red Lion
Endress Houser
Endress Houser
Premium
Premium
KEJE Electric
KEJE Electric
Sterling Engineering
Sterling Engineering
Fietest
httpswww.fietest.com
J K Machines
J K Machines
Filtermist
Filtermist
Exor
Exor
IMTMA
IMTMA
Prostarm
Prostarm
Wika Instruments India
Wika Instruments India